TROUBLE SHOOTING GUIDE
SYMPTOM CAUSE SOLUTION
Detector chatters • Using detector • Use detector
or beeps erratically indoors outdoors only
• Using detector near • Move away
power lines
from power lines
• Using 2 detectors in • Keep 2 detectors
close proximity at least 20’ apart
• Highly oxidized • Only dig up
buried object repeatable
signals
• Environmental
Reduce sensitivity
electromagnetic until erratic
interference signals cease
Constant low tone
Discharged battery
• Replace battery
or
constant repeating
tones
Wrong type of • Use only 9V
battery alkaline battery
or rechargeable
LCD does not lock • Multiple targets
Move coil slowly
on to one target ID present at different angles
or detector emits • Highly oxidized
multiple tones target
Sensitivity set • Reduce sensitivity
too high
No power, no • Dead battery • Replace battery
sounds
• Cord not connected
securely
Check connections
TROUBLE SHOOTING
19